B–63323EN/03
6. CONNECTION OF I/O UNITS TO
MACHINE INTERFACE
257
Maximum load current in ON state 200mA or less
Saturation voltage in ON state Max. 1V (When load current is 200mA)
Withstand voltage 24V"20% or less
(including momentary values)
Leakage current in OFF state 20µA or less
Delay time Driver delay : Max. 50µs
Need to consider about the serial communication (I/O Link) delay
between CNC and operator’s panel 2ms(MAX)+Scan cycle of
ladder (Scan cycle is different each CNCs).
Symbol English Meaning of key
AUTO
AUTO mode selection signal; Sets automatic operation mode.
EDIT
EDIT mode selection signal; Sets program edit operation mode.
MDI
MDI mode selection; Sets MDI mode.
REMOTE
DNC operation mode; Sets DNC operation mode.
REF
RE
TURN
Reference position return mode selection; Sets reference position return mode.
JOG
JOG feed mode selection; Sets jog feed mode.
INC
JOG
Step feed mode selection; Sets step feed mode.
HANDLE
Manual handle feed mode selection; Sets manual handle feed mode.
TEACH
Teach–in jog (reach–in handle) mode selection signal; Sets teach–in jog (teach–in
handle) mode.
SINGLE
BLOCK
Single block signal; Executes program one by one. This key is used to check a pro-
gram.
6.12.6.6
General–purpose DO
signal definition
6.12.7
Key Symbol Indication
on Machine Operator’s
Panel
6.12.7.1
Meaning of key symbols