7. CONNECTION TO CNC PERIPHERALS
B–63323EN/03
296
Serial communications using optical fiber cable is used as the servo
interface.
For details on connections relating to the control motor amplifier ALPHA
series, refer to the FANUC SERVO AMPLIFIER ALPHA Series
Specifications (B–65162E).
COP10A2
COP10A1
COP10B
<1>
COP10A
COP10B
<2>
COP10A
COP10B
<3>
COP10A
COP10B
COP10A
CP11A
CNF1
CNC
Main CPU or
additional axis
Axis control card
Servo amplifier:
All servo amplifiers
in this example are
single–axis amplifi-
ers. The numbers
in the branckets in-
dicate the axis
numbers of the
axes.
Separate detector
interface module:
A unit supporting
servo HRV3 is re-
quired.
External
24–VDC power
– When servo HRV3 is used, an axis control card supporting servo
HRV is required. In addition, when servo HRV3 is used, the servo
amplifiers used must be amplifiers for high–speed HRV current con-
trol or servo HRV3 amplifiers.
– Up to eight axes in total can be connected to the FSSB line.
– The total number of axes and separate detectors connected to one
servo card must be 10 or less. (Nine in total in this example)
– Cards used for two to eight axes are all classified as TYPE A.
7.6
SERVO INTERFACE
(FSSB)
7.6.1
Connection Example
When High–Speed HRV
Current Control is not
Used