6. CONNECTION OF I/O UNITS TO
MACHINE INTERFACE
B–63323EN/03
240
To the connector CA64 (IN) shown in the figure below, connect the
required power for operating the operator’s panel and the power for
general–purpose DI. For easier power supply branching, the power
supplied from CA64 (IN) is directly output to CA64 (OUT). When power
supply branching is required, use CA64 (OUT).
01 +24V
02 0V
03
CA64(IN)
+24V power
01 +24V
02 0V
03
CA64(OUT)
+24V power
AMP Japan
1–178288–3 (housing)
1–175218–5 (contact)
NOTE
1 Both connectors CA64(IN) and CA64(OUT) are same specification. And there is not indication
of (IN) and (OUT) on the PCB.
2 Power supply for the operator’s panel must not turn off at operation. If +24V is turned off at
operation, CNC happen to get system alarm(Communication alarm between CNC and
operator’s panel). +24V for operator’s panel must be supplied before or same time CNC power
on.
6.12.3.2
Power supply
connection