B–63443EN/02
5. STATUS SIGNALSPMC INTERFACE
135
When an alarm is triggered in the Power Mate, an alarm message is
displayed on the CRT or DPL and the alarm signal AL turns to “1”. When
the cause of the alarm is corrected and the Power Mate is reset, the alarm
state of Power Mate is cleared and the AL signal turns to “0”.
The followings are alarm states:
(a) TH alarm
(b)TV alarm
(c) P/S alarm
(d)Overtravel alarm
(e) Overheat alarm
(f) Servo alarm
If the battery voltage to hold a program in memory during power
interruption is lower than the specified value, this signal turns to “1”. The
Power Mate informs the PMC of the battery alarm (BAL = 1). Generally,
a lamp is used to indicate the alarm in order to alert the operator. (When
using a unit that has no indicator, such as a CRT or DPL, a lamp must be
provided to act as an indicator.)
The CNC reset signal RST turns to “1” for any of the following reasons:
(1) While RESET button on the CRT/MDI panel is being pressed.
(2) While the external reset signal ERS[4.2] turns to “1”.
(3) While the emergency stop signal
*
ESP[4.1] turns to “0”.
(4) While reset & rewind signal RRW [4.3] turns to “1”.
The machine tool operator can activate this signal to allow it to reset on
the ladder.
The RST signal output time is extended to prevent the PMC from failing
to read a signal. The extention time can be set in units of 16 msec using
parameter No. 3017. The RST signal output time is obtained by:
(Reset processing time)+(parameter value) 16 msec.
PRSTCT 16m sec
Reset
Processing
Reset
Reset ON
RST signal
( PRSTCT : Parameter No.3017 )
NOTE
Reset processing time requires at least 16 msec. This time
will be longer on optional configurations.
5.1
ALARM SIGNAL
(OUTPUT) AL
<F001#0>
5.2
BATTERY ALARM
SIGNAL (OUTPUT)
BAL <F001#2>
5.3
RESET SIGNAL
(OUTPUT) RST
<F001#1>