To perform the gear changing, the maximum spindle speed for each gear
select signal issued from the PMC side must be set by parameter No.
3741-3744.
The gear select signal is a 2 bit code signal (GR1, GR2). The relationship
between the signal and gear number is :
GR1 GR2 Gear No.
Parameter No. for max.
spindle speed
0 0 1 No. 3741
1 0 2 No. 3742
0 1 3 No. 3743
1 1 4 No. 3744
Assume that gear switching is two stage switching. If the spindle speed
with the output voltage 10 V is 1000 min
–1
for the low speed gear (G1)
and 2000 min
–1
for the high speed gear (G2), set these speeds by the
parameter No. 3741, 3742. In this case, the analog voltage has the linear
relationship shown below.
600min
–1
1000min
–1
When gear
2 selected
When gear
1 selected
Volt
0
V
2
V
1
10
2000min
–1
N
When spindle speed S=600 is given, V
1
(for G1) or V
2
(for G2) is
calculated inside the CNC and output to the machine side.
V1: 6(V)
V2: 3(V)
The value of output voltage V is calculated automatically from the
following equations:
V=
10N
R
R: Spindle speed at 10V output voltage
N: Spindle speed given by S5-digits
This is equivalent to the G97 mode for constant surface speed control.
See Section 18.6 for operations during the constant surface speed control
mode (G96).
In addition, parameter No. 3772 (upper limit to the spindle speed) can
specify speed clamping for all gear positions.
D Details of gear selection
method (Input of GR1,
GR2)