B–63443EN/02
H. DESCRIPTION OF PARAMETERS
APPENDIX
327
3741 Maximum spindle speed for gear 1
3742 Maximum spindle speed for gear 2
3743 Maximum spindle speed for gear 3
3744 Maximum spindle speed for gear 4
Data type: Word
Unit of data: min
–1
Valid data range: 0 to 32767
Set the maximum spindle speed corresponding to each gear.
Spindle speed command
(S command)
Spindle motor
min. clamp speed
(parameter No. 3735)
Spindle motor speed
Gear 1
max. speed
Max. output
(4095, 10 V)
Spindle motor
max. clamp speed
(parameter No. 3736)
Gear 2
max. speed
Gear 3
max. speed
Fig.H.13 Maximum Spindle Speed Corresponding to Gear 1/2/3
3770 Axis as the calculation reference in constant surface speed control
Data type: Byte
Valid data range: 0, 1, 2
Set the axis as the calculation reference in constant surface speed
control.
NOTE
When 0 is set, constant surface speed control is always
applied to the X–axis. In this case, specifying P in a G96
block has no effect on the constant surface speed control.
3771 Minimum spindle speed in constant surface speed control mode (G96)
Data type: Word
Unit of data: min
–1
Valid data range: 0 to 32767
Set the minimum spindle speed in the constant surface speed control
mode (G96).
The spindle speed in constant surface speed control is clamped to the
speed given by parameter 3771.