12. AUTOMATIC OPERATION
B–63443EN/02
PMC INTERFACE
168
When the cycle start signal (ST) is turned to “1”, then turned to “0” when
automatic operation (MEM) is selected, the Power Mate enters automatic
operation state and operation starts. At the same time, the cycle start lamp
signal (STL[12.3]) turns to “1”.
The cycle start signal (ST) is ignored when:
(1) Automatic operation mode is not selected;
(2) Feed hold signal (*SP) is “0”;
(3) Emergency stop signal (*ESP) is “0”;
(4) External reset signal (ERS) is “1”;
(5) During sequence number search;
(6) Alarm state is displayed on CRT/MDI;
(7) NOT READY is displayed on CRT/MDI;
(8) STL signal is output during automatic operation start ; or
(9) Axis movement commanded by the previous command is not ended.
When the following occurs during automatic operation, the machine stops
and the STL signal turns to “0”:
(1) *SP signal is “0”;
(2) *ESP signal is “0”;
(3) ERS signal is “1”;
(4) RESET button is pushed;
(5) Commands of one block are ended in single block state;
(6) Manual data input command execution is ended;
(7) End of record code is read during automatic operation;
(8) Axis movement stops by an alarm; or
(9) Mode is switched to manual handle/step feed or jog feed.
Generally, the cycle start signal is input by pushbutton.
Table 12.1 Status of Operation
Signal name
Cycle start Feed hold Automatic
State of the CNC
lamp
STL
lamp
SPL
operation lamp
OP
Cycle start state Ę Ę
Feed hold state Ę Ę
Automatic operation stop
state
Ę
Reset state
Ę indicates the signal “1”
(1) Cycle start state
Indicates that the Power Mate is executing automatic operation
command.
(2) Feed hold state
Indicates that the Power Mate is not executing automatic operation
ommand. The command to be executed remain.
12.1
CYCLE START
SIGNAL (INPUT) ST
<G007#2>