B–63443EN/02
H. DESCRIPTION OF PARAMETERS
APPENDIX
325
TCW and CWM: Voltage polarity when the spindle speed voltage is
output
TCW CWM Voltage polarity
0 0 Both M03 and M04 positive
0 1 Both M03 and M04 negative
1 0 M03 positive, M04 negative
1 1 M03 negative, M04 positive
3708 SAT SAR
(Bit)#7 #6 #5 #4 #3 #2 #1 #0
Data type: Bit
SAR: The spindle speed arrival signal is:
0: Not checked
1: Checked
SAT Check of the spindle speed arrival signal at the start of
executing the thread cutting block
0 : The signal is checked only when SAR, #0 of parameter
3708, is set.
1 : The signal is always checked irrespective of whether SAR
is set.
NOTE
When thread cutting blocks are consecutive, the spindle
speed arrival signal is not checked for the second and
subsequent thread cutting blocks.
3730 Data used for adjusting the gain of the analog output of spindle speed
Data type: Word
Unit of data: 0.1 %
Valid data range: 700 to 1250
Set data used for adjusting the gain of the analog output of spindle
speed.
(Adjustment method)
(1) Assign standard value 1000 to the parameter.
(2) Specify the spindle speed so that the analog output of the
spindle speed is the maximum voltage (10 V).
(3) Measure the output voltage.
(4) Assign the value obtained by the following equation to
parameter No. 3730.
10 (V)
Measured data (V)
Set value=
1000
(5) After setting the parameter, specify the spindle speed so that
the analog output of the spindle speed is the maximum
voltage. Confirm that the output voltage is 10 V