Sheet
Title
Draw
No.
Ed. Date Design Description
Date Oct.29.2004 Desig. Apprv.
4/7
16i/18i/21i/160i/180i/210i/160is/180is/210is-MODEL B
MAINTENANCE MANUAL
bout the error messages of Embedded Ethernet
B-63525EN/02-5
GETTING PARAMETER FROM DHCP SERVER
The network parameters are gotten from the DHCP server.
This is not an error message.
SET DEFAULT FOCAS1/ETHERNET PARAMETER
The default parameter of FOCAS1/Ethernet function was set.
This is not an error message.
SET DEFAULT DNC1/ETHERNET PARAMETER
The default parameter of DNC1/Ethernet function was set.
This is not an error message.
CHANGED (%s) BY DHCP SERVER
The network parameter[%s] was changed by the DHCP server.
This is not an error message.
8.9.2 EMB_ETH FACTOLINK LOG Screen
FACTOLINK IP ADDRESS(%s) IS INVALID
The setting(%s) of the IP address for FACTOLINK server is incorrect.
Correct the IP address.
FACTOLINK PORT NUMBER(%d) IS INVALID
The setting(%d) of the TCP port number for FACTOLINK server is
incorrect. Correct the TCP port number.
FACTOLINK SERVER ISN'T ALIVE
The FACTOLINK server cannot be found on the network. Check if the
FACTOLINK server is connected to the network correctly.
ROUTER IP ADDRESS(%s) IS INVALID
The setting(%s) of the IP address of the router is incorrect. Correct the
IP address of the router.
ROUTER ISN'T ALIVE
The router cannot be found on the network. Check if the router is
connected to the network correctly.
Ping Error (%d)
An error(%d) occurred when the PING command was sent to the
FACTOLINK server.
Err NOT CONNECTED
A disconnection request or data send request was issued to a
non-connected port. Connect to the FACTOLINK server again.
Err ALREADY CONNECTED
Connection request was issued again to the already connected port.