B–63525EN/02
7.INTERFACE BETWEEN CNC AND PMC
493
D Trace function start (PMC–SB7:K906.5)
Manual (0): The trace function starts trace operation when the
[EXEC] soft key is pressed.
Automatic (1): The trace function starts sampling automatically after
the power is turned on.
D Enable editing (PMC–SB7:K901.6, PMC–SA1:K18.6)
No (0): The editing of a sequence program is disabled.
Yes (1): The editing of a sequence program is enabled.
D Save after editing (PMC–SB7:K902.0, PMC–SA1:K19.0)
No (0): After ladder editing, the F–ROM is not written to
automatically.
Yes (1): After ladder editing, the F–ROM is written to
automatically.
D Enable memory write (PMC–SB7:K900.4, PMC–SA1:K17.4)
No (0): The forcing function and the override function are
disabled.
Yes (1): The forcing function and the override function are
enabled.
D Data table GRP setting display (PMC–SB7:K900.7, PMC–SA1:K17.7)
Yes (0): The PMC parameter data table control screen is
displayed.
No (1): The PMC parameter data table control screen is not
displayed.
D Disable PMC program read (PMC–SB7:K900.0, PMC–SA1:K17.0)
No (0): The reading of a sequence program is enabled.
Yes (1): The reading of a sequence program is disabled.
D IO Group selection (PMC–SB7:K906.1)
Hide (0): The I/O assignment data selection function setting
screen is not displayed.
Show (1): The I/O assignment data selection function setting
screen is displayed.
D PMC program execution (PMC–SB7:K900.2, PMC–SA1:K17.2)
Automatic (0): After the power is turned on, a sequence program is
automatically executed.
Manual (1): A sequence program is executed by pressing the
sequence program execution soft key.
D Enable PMC stop (PMC–SB7:K902.2, PMC–SA1:K19.2)
No (0): The execution/stop operation of a sequence program
is disabled.
Yes (1): The execution/stop operation of a sequence program
is enabled.
D Enable the programmer function (PMC–SB7:K900.1, PMC–SA1:
K17.1)
No (0): The built–in programmer function is not operated.
Yes (1): The built–in programmer function is operated.