B–63525EN/02
7.INTERFACE BETWEEN CNC AND PMC
461
The setting address, condition and counter are displayed at the title line.
“MODE:ON : X0000. 0 : 0 : 0001 ”
COUNT: Trigger checking number (default 1)
POINT: Trigger checking number (default 0)
0 : the top of the 1st level
1 : after END1 execution
2 : after END2 execution
3 : after END3 execution
ADR: Trigger setting address
ON: Rising edge detection (TRGON)
OFF: Falling edge detection (TRGOFF)
* Setting form adr ;p1 ;p2+[TRGON/TRGOFF]soft key
NOTE
“;”=“EOB”
Adr (trigger address) ;p1 (trigger point) ;p2 (trigger checking number
(1 to 65535))
* Because parameters are stored in the nonvolatile memory, they are not
lost even if the power is turned off.
When bit 2 of keep relay K18 is set to 1 after parameters for sampling
are specified, the trigger function automatically starts when the power
is turned on.
For this operation, depress [TRIGER] soft key to bring the following
menu.
SEARCH ADRESS TRIGER WINDOW
NEXT
TRGON TRGOFF START
DUMP DPARA TRGSRC INIT
RET
The function of the [TRIGER] soft key is explained below:
(1)[TRGON] : The trigger function is stopped when a specified address
signal goes high (is turned ON).
(2)[TRGOFF] : The trigger function is stopped when a specified address
signal goes low (is turned OFF).
(3)[START] : Pressing this key switches between trigger function
execution and trigger function termination. While the
trigger function is being executed, the “TRG” indication
blinks.
D Display of setting trigger