8. EMBEDDED ETHERNET FUNCTION
B–63525EN/02
620
An example of minimum setting required to operate the DNC1/Ethernet
function on a small network is provided below.
In this example, one personal computer is connected to two CNCs
through DNC1/Ethernet.
D On Personal Computer 1, the client of the DNC1/Ethernet function
operates.
D On CNC 1 and CNC 2, the server of the DNC1/Ethernet function
operates.
10BASE–T or 100BASE–TX
CNC 1 CNC 2
PC 1
CNC 1 CNC 2
IP address 192.168.1.1 192.168.1.2
Subnet mask 255.255.255.0 255.255.255.0
Router IP address None None
TCP port number 8193 8193
UDP port number 8192 8192
Time interval 100 100
PC 1
IP address 192.168.1.101
Subnet mask 255.255.255.0
Default gateway None
FANUC_C4_SERVER 8192/udp
CNC 1 Machine No. 1
NC IP address 192.168.1.1
NC TCP port number 8193
CNC 2 Machine No. 2
NC IP address 192.168.1.2
NC TCP port number 8193
8.3.2.4
Using the DNC1/Ethernet
function on a small
network
The Ethernet parameter screen is used for
setting.
”Microsoft TCP/IP property” of the personal computer
(Windows NT) is used for setting.
Refer to ”FANUC Personal Computer FA System Win-
dows NT Version OPERATOR’S MANUAL”.