bout the error messages of Embedded Ethernet
B-63525EN/02-5
Err FAIL TO CONNECT SOCKET
Failed to connect to the FACTOLINK server.
Check the FACTOLINK server is activated normally.
8.9.3 EMB_ETH FOCAS1/ETHER LOG Screen
EMB_ETH PMC LOG Screen
TCP PORT NUMBER(%d) IS INVALID
The setting(%d) of the TCP port number for FOCAS1/Ethernet is
incorrect. Correct the TCP port number.
UDP PORT NUMBER(%d) IS INVALID
The setting(%d) of the UDP port number is incorrect. Correct the TCP
port number.
UDP INTERVAL TIME(%d) IS INVALID
The setting(%d) of the time interval for UDP transmission is incorrect.
Correct the time interval.
ALL TASKS(C%d) ARE BUSY
The FOCAS1/Ethernet function is already engaged in communication
with five applications. Terminate the communication with unnecessary
applications on the personal computer.
Err TakeOutPduHeader()
An error occurred under waiting the receiving data.
Err TakeOutPduContents()
An error occurred under receiving the data.
Err recv() [%d]
A reception error(%d) occurred.
Err EthInitiateDownload() [%d]
An error occurred when starting download data. The error code is [%d].
Err EthAbortDownload() [%d]
An error occurred when aborting download data. The error code is [%d].
Err EthTerminateDownload() [%d]
An error occurred when terminating download data. The error code is
[%d].
Err EthInitiateUpload() [%d]
An error occurred when starting upload data. The error code is [%d].