B–63525EN/02
9. DIGITAL SERVO
677
The FSSB setting screen displays FSSB–based amplifier and axis
information. This information can also be specified by the operator.
1. Press function key
SYSTEM
.
2. To display [FSSB], press continuous menu key
several times.
3. Pressing soft key [FSSB] causes the AMP SET screen (or the
previously selected FSSB setting screen) to appear, with the following
soft keys displayed.
AMP (OPRT)MAINTEAXIS
The FSSB setting screens include: AMP SET, AXIS SET, and AMP
MAINTENANCE.
Pressing soft key [AMP] causes the AMP SET screen to appear.
Pressing soft key [AXIS] causes the AXIS SET screen to appear.
Pressing soft key [MAINTE] causes the AMP MAINTENANCE
screen to appear.
1) Amplifier setting screen
The amplifier setting screen consists of two sections: the first section
displays information about the slave, while the second section
displays information about the pulse modules.
AMPLIFIER SETTING O1000 N00001
NO. AMP SERIES UNIT CUR. AXIS NAME
1A1–L α SVM–HV 40AL 1 X
2A1–M α SVM 12A 2 Y
3A2–L β SVM 40A 3 Z
4A3–L α SVM 20A 4 A
5A3–M α SVM 40A 5 B
7A4–L α SVU 240A 6 C
NO. EXTRA TYPE PCB ID
6 M1 A 0000 DETECTOR(8AXES)
8 M2 B 12AB
>_
MDI **** *** *** 13:11:56
[ AMP ][ AXIS ][ MAINTE ][ ][(OPRT)]
The amplifier setting screen consists of the following items:
D NO. (slave number)
The numbers of up to ten slaves (up to eight amplifiers and up to two
pulse modules) connected via the FSSB are displayed sequentially,
with the one nearest to the CNC being number 1.
D AMP (amplifier type)
The amplifier type display consists of the letter A, which stands for
“amplifier,” a number that indicates the placing of the amplifier, as
counted from that nearest to the CNC, and a letter such as L (first axis)
or M (second axis) indicating the placing of the axis in the amplifier.
D Display