B–63525EN/02
8. EMBEDDED ETHERNET FUNCTION
611
The NC parameters related to the FACTOLINK function are described
below.
0802 Communication channel
[Data type] Byte
[Valid data range] 21: Select the embedded Ethernet.
#7 #6 #5 #4 #3 #2 #1 #0
0810 MONO TIME BGS
[Data type] Bit
BGS When the FACTOLINK screen is not displayed:
0 : Logging is performed in the background.
1 : Logging is not performed.
TIME Selects the time display format:
0 : ”97/11/12 00:00” format is used.
1 : ”Wed Nov 12 00:00:00” format is used.
MONO When the FACTOLINK screen is displayed:
0 : Two–tone monochrome display is used.
1 : Color display is used.
0811 Type of logging
[Data type] Byte
[Valid data range] 0, 1, 10, 20, 21
0 : D address area
1 : R address area
10 : Fixed data only
20 : D address area + fixed data
21 : R address area + fixed data
0812 PMC address for logging data
[Data type] Word
[Valid data range] 0 to 65535
Set a start PMC address for storing logging data.
0813 Data length of logging data
[Data type] Word
[Unit of data] Number of bytes
[Valid data range] 0 to 65535
Set the data length of logging data.
8.3.1.3
Parameters
Parameters