4. STAND–ALONE TYPE i SERIES HARDWARE
B–63525EN/02
318
GR1(Green) +5V(Green)
GR2(Green) HDD(Green)
GR3(Green) CNC(Green)
GR4(Green) CRD(Green)
RE1(Red) BUS(Red)
RE2(Red) BAT (Red)
RE3(Red) FAN(Red)
RE4(Red) TRM(Red)
or
*6
CNH3 (HDD Signal)
CD34 (FDD Signal)
COP7
Name 1
(*6)
Name 2
(*6)
Color Status
GR1 +5V Green Lights when +5 V is supplied.
GR2 HDD Green Lights when the HDD is accessed.
GR3 CNC Green Lights when the CNC operates normally.
GR4 CRD Green Lights when PCMCIA is accessed.
RE1 BUS Red Lights when transfer over the HSSB is interrupted. Possible causes are
shown below.
S The CNC unit is not powered.
S The optical fiber cable is not connected.
S The interface on the CNC side failed.
S The CNC display unit with PC functions or the PANEL i failed.
RE2 BAT Red Indicates a battery alarm. Replace the battery installed in the CNC display
unit with PC functions or in the PANEL i.
RE3 FAN Red Lights when the basic unit fan or HDD fan stops. Replace the failed fan.
RE4 TRM Red Indicates a temperature alarm. This LED lights when the CPU detects a
high temperature that falls outside the use range. (This decreases the
operating speed of the CPU.)
*6:These labels may vary with the drawing number or version number of
the main board.
Short plug Settings Location
SW5
SW7
(A20B–2100
–0690 to –0693)
Reserved Do not change the factory–set
defaults.
SW5
SW7
: Open
: Short
: Short (PANEL i)
SW5
TM7
(A20B–2100
–0780 to –0785)
Reserved Do not change the factory–set
defaults.
SW5
TM7
: Short (PANEL i)
Open (CNC display
unit with PC functions)
TM10 Reserved This short plug is provided for
testing purpose.
Be sure to insert this plug.
TM10
: Short
D LED display
D Short plug settings