B-63790EN/01 4.DESCRIPTION OF PARAMETERS
- 101 -
1542 Post-interpolation acceleration/deceleration time constant (for medium
finishing)
[Input type] Parameter input
[Data type] Integer axis
[Unit of data] msec
[Valid data range] 0 - 4000
Stores the post-interpolation acceleration/deceleration time constant
for the medium machining parameter set. Usually, the acceleration is
entered from the HPCC (SETTING) screen. If a different value needs
to be set for an axis, this parameter must be directly specified. To
make the setting effective during operation, the "SELECT ACTIVE"
key must be pressed on the HPCC (SETTING) screen.
1544 Corner feedrate difference (for medium finishing)
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm/min, inch/min, degree/min (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 - +240000.0)
Stores the corner feedrate difference for the medium machining
parameter set. Usually, the difference is entered from the HPCC
(SETTING) screen. If a different value needs to be set for an axis, this
parameter must be directly specified. To make the setting effective
during operation, the "SELECT ACTIVE" key must be pressed on the
HPCC (SETTING) screen.
1549 Feed-forward factor (for medium finishing)
[Input type] Parameter input
[Data type] Integer axis
[Valid data range] 0 - 10000
Stores the feed-forward factor for the medium machining parameter
set. Usually, the factor is entered from the HPCC (SETTING) screen.
If a different value needs to be set for an axis, this parameter must be
directly specified. To make the setting effective during operation, the
"SELECT ACTIVE" key must be pressed on the HPCC (SETTING)
screen.
1553 Acceleration level (for medium finishing)
[Input type] Parameter input
[Data type] Integer
[Unit of data] %
[Valid data range] 0 - 200
Stores the acceleration level for the medium machining parameter set.
Usually, the level is entered from the HPCC (SETTING) screen and,
therefore, this parameter need not be directly specified.