4.DESCRIPTION OF PARAMETERS B-63790EN/01
- 168 -
#6 DSM Specifies whether the machine positions displayed on the screen
include the acceleration/deceleration control delay.
0: The positions do not include the acceleration/deceleration
control delay.
1: The positions include the acceleration/deceleration control
delay.
#7 DVM Specifies whether the machine positions displayed on the screen
include the servo delay (positional deviation) .
0: The positions displayed on the screen do not include the servo
delay (positional deviation) .
1: The positions displayed on the screen include the servo delay
(positional deviation) .
#7 #6 #5 #4 #3 #2 #1 #0
2203 NNO TLN MCN
[Input type] Parameter input
[Data type] Bit
#1 MCN The machine positions are displayed on the screen:
0: In millimeters for a millimeter machine or in inches for an inch
machine irrespective of the unit of data.
1: In millimeters for metric input or in inches for inch input.
#4 TLN T codes displayed on the program check screen and T codes that can
be read with system variables indicate
0: Pot numbers
1: Tool numbers
#7 NNO When operator messages are set by external data input/output,
messages set with different numbers are:
0: Line-fed.
1: Not line-fed.
#7 #6 #5 #4 #3 #2 #1 #0
2204 DA
NOS
[Input type] Parameter input
[Data type] Bit
#0 NOS Specifies whether the actual spindle speed is displayed.
0: Displayed
1: Not displayed
The actual spindle speed is displayed based on the feedback by the
position coder installed in the spindle. For serial spindles, the actual
spindle speed can be displayed based on the speed monitor data from
the spindle motor, depending on the setting of ASD (bit 4 of
parameter No. 5820) .
Specify 1 for the machine without the position coder because the
machine does not require threading and feed each rotation or if you do
not want to display the actual spindle speed.