4.DESCRIPTION OF PARAMETERS B-63790EN/01
- 392 -
7631 Controlled axis number of an index table indexing axis
NOTE
After this parameter has been set, the power must be
off turned off then back on for the setting to become
effective.
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - Max axes
Set the controlled axis number of an index table indexing axis.
When 0 is set, the fourth axis is assumed.
7632 M code used to specify the negative-direction rotation of an index table
indexing axis
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 127
0: The rotation direction of an index table indexing axis is determined
by the setting of the parameter (7602#4 INC) and command.
1 to 127: The rotation direction of an index table indexing axis is
always positive. The rotation direction is negative only when a move
command is specified together with the M code set.
7633 M code for turning off synchronization in synchronous control and twin table
control
[Input type] Parameter input
[Data type] Integer
[Valid data range] 1 - 999999999
Specify an M code for switching from synchronous operation to
independent operation or normal operation.
The M code set in this parameter is not buffered.
7634 M code for turning on synchronization in synchronous control and twin table
control
[Input type] Parameter input
[Data type] Integer
[Valid data range] 1 - 999999999
Specify the M code that causes switching from independent or normal
operation to synchronous operation.
The M code specified for this parameter is treated as an M code
without buffering.