4.DESCRIPTION OF PARAMETERS B-63790EN/01
- 348 -
7050 G code used to call the custom macro of program number 9010
7051 G code used to call the custom macro of program number 9011
7052 G code used to call the custom macro of program number 9012
7053 G code used to call the custom macro of program number 9013
7054 G code used to call the custom macro of program number 9014
7055 G code used to call the custom macro of program number 9015
7056 G code used to call the custom macro of program number 9016
7057 G code used to call the custom macro of program number 9017
7058 G code used to call the custom macro of program number 9018
7059 G code used to call the custom macro of program number 9019
[Input type] Parameter input
[Data type] Integer
[Valid data range] From -999 though 999 excluding 0, 5, 65, 66 and 67
Set the G codes used to call the custom macros of program numbers
9010 through 9019. However, note that when a negative value is set in
this parameter, it becomes a modal call. For example, if this
parameter is set to -11, the modal call mode is entered by G11.
Whether the modal call is equivalent to G66 or G66.1 depends on bit
3 (MGE) of parameter No. 7000.