9.TOTAL CONNECTION DIAGRAM SVM B-65322EN/02
- 78 -
[Receptacle contact]
Two receptacle contact types are available, so as to support
different conductor diameters. Be sure to select the
receptacle contact that matches the servo axis you use.
Rectangle contact
model number
Conductor
size
(mm
2
)
Conductor
size
AWG
Insulation outer
diameter (mm)
Manual tool
model number
Manufacture
L size 1-175218-2 0.5- 1.25 20/18/16 1.8-2.8 91558-1 Tyco Electronics AMP
[Connector and tool ordering information]
Connectors (including housings and contacts) and tools can
be purchased directly from Tyco Electronics AMP. They
can be ordered as options also from FANUC as listed
below.
Ordering number Description
A06B-6130-K200
Housing : Incorrect-insertion prevent key 175363-3 (1pcs.)
Incorrect-insertion prevent key 1318095-2 (1pcs.)
Contact : L size 1-175218-2 (10pcs.)
Applicable wire diameter:
0.5-1.25mm
2
, AWG20/18/16
Applicable tool: 91558-1 (not included in this kit)
(b) SVM1-40i, SVM1-80i
i SVM
CZ4
L1
L2
L3
Receptacle housing
B1
A1
B2
A2
[Receptacle housing]
Use the following receptacle housing.
Manufacturer-defined
model
Specification of
the key
Manufacture
1-917807-2 XX Tyco Electronics AMP
[Receptacle contact]
Rectangle contact
model number
Conductor
size
(mm
2
)
Conductor
size
AWG
Insulation outer
diameter (mm)
Manual tool
model number
Manufacture
S size 316040-6 1.25 – 2.20 16/14 3.0-3.8 234170-1 Tyco Electronics AMP