B-65322EN/02 I/O Link 9.TOTAL CONNECTION DIAGRAM
- 211 -
9.1.3 SVM1-4i and SVM1-20i
Example for sharing a magnetic contactor
This subsection shows a connection example of a 2-axis system using
two SVM units which are the SVM1-4i or SVM1-20i.
In this example, a separated regenerative discharge unit is connected
but no external pulse generator is connected to the SVM unit for the
first axis (the unit nearer the CNC), while no separated regenerative
discharge unit is connected but an external pulse generator is
connected to the SVM1unit for the second axis.
CNC
Stabilized
power supply
24 VDC
3-phase : 200 to 240 VAC
1-phase : 220 to 240 VAC
5 A
Circuit
breaker
24 V power
supply for
motor brake
CZ7
CX30
CXA20
CXA19B
CXA19A
JD1B
JD1A
JA72
FUSE
CX5X
SVM1-4
i
or
SVM1-20
i
JF1
Lightning
surge
absorber
CZ7
CX29
CX30
CXA20
CXA19B
CXA19A
JD1B
JD1A
FUSE
CX5
X
JA34
JA72
JF1
JA34
Battery
case
SVM1-4
i
or
SVM1-20
i
Magnetic
contacto
C line
filter
Circuit
breaker
Separated
regenerative
discharge
resistor
CX29
K20
K11 K6 K9
K20
K2
K4
K3
K10
K3 K1
K7 K7
K5
K5
K21
K21
K8
K2
K22
K10
K1
Machine
operator’s
panel
Emergency
stop switch
External pulse
generator
CAUTION
1 A circuit breakers, magnetic contactor, and AC line filter are
always required.
2 Use the stabilized 24VDC power supply for the
β
i SVM.
24VDC power supply for the
βi
SVM and 24VDC power
supply for the motor brake cannot be shared.
3 If an alarm that turns off the magnetic contactor is issued in
an amplifier, an alarm indicating DC link voltage shortage is
issued in the other amplifiers.