B-65322EN/02 SVM 9.TOTAL CONNECTION DIAGRAM
- 93 -
9.2.11 Details of Cable K9
βi SVM
Battery case
06B-6050-K060
CXA19A
0V
6V
24V
0V
2
B3
24V
0V
ESP
BAT
Battery
06B-6050-K061
Crimp terminal : 1.25-2
pplicable wire : 0.3 to 0.85mm
2
D-2000 series
Housing : 1-1318119-3
Contact : 1318107-1
pplicable wire : 0.3 to 0.85mm
2
Manufacture : Tyco Electronics AMP
For connection tools, see Subsection 9.2.3.
NOTE
1 Because the battery requires periodic
maintenance, the above connection method is
recommended, where easily available commercial
batteries (four size D alkaline batteries) can be
used.
2 Servo motors for six axes can be connected to one
battery unit.
3 If servo motors for six axes are connected to the
battery unit, the service life of the battery unit is
about two years for the βi series servo motors or
about one year for the β series servo motors. The
battery should be replaced periodically.
WARNING
Do not connect more than one battery to the same
BATL(B3) line. Otherwise, a short-circuit will
occur between the output voltages of different
batteries, possibly resulting in the batteries
becoming very hot, which is dangerous.