9.TOTAL CONNECTION DIAGRAM SVPM B-65322EN/02
- 144 -
9.3.1.2 Details of cable K6
Cable K6 is used to control the magnetic contactor if it is installed
outside the unit.
Spark
killer
Coil
Internal
contact
External power supply
(must match the coil voltage of the
user's equipment)
SVPM
Connector Manufactured by Tyco Electronics AMP
D-3200 series
Housing 2-178128-3 (1 pcs.)
Contact 1-175218-2 (2 pcs.)
(FANUC ordering information: A06B-6134-K201)
Cable Two-conductor polyvinyl heavy-duty power cable (JIS C3312),
conductor size of 1.25 mm
2
(50/0.18), PVC sheath 9.6 mm in
diameter
Internal-contact specification:
Resistive load
(cos
φ=1)
Inductive load
(cosφ=0.4, L/R=7msec)
Rated load 250VAC, 5A / 30VDC, 5A 250VAC, 2A / 30VDC, 2A
Maximum contact
rating
5A 5A
NOTE
Always install a spark killer (CR) that matches the
magnetic contactor to protect the internal contacts.
The following table lists the recommended
capacitances and resistances.
Coil voltage C R
24 VDC 0.22 µF
22
Ω
100 to 230 VAC 0.1 µF
220
Ω