B-65322EN/02 SVM 9.TOTAL CONNECTION DIAGRAM
- 91 -
9.2.10 Details of Cable K8
βi SVM
CX30
3
1
D-2000 series
Housing : 2-1318120-3
Contact : 1318107-1
pplicable wire: 0.3 to 0.85mm
2
Manufacture : Tyco Electronics AMP
24V
Receiver
circuit
*ESP
For connection tools, see Subsection 9.2.3.
(1) When the contact is ON (closed), the servo motor is operational.
When the contact is OFF (open), the external magnetic contactor
(MCC) is in the off state, and the servo motor does not operate.
(2) When the contact is set to OFF (open) while the motor is turning,
the servo motor is stopped by the dynamic brake.
(3) The contact input signal is defined as follows:
<1> As the external contact capacity, a voltage of at least 30
VDC and a current of at least 100 mA are required.
<2> When contactless input is used, the significant levels (the
voltage across the input pin) are as follows:
Low level "logic 0": 2 V or less
High level "logic 1": 20 V or more