B-65322EN/02 SVM 3.SPECIFICATIONS
- 17 -
3.6.3 When Amplifier Models SVM-40i and SVM-80i Are Used
If the amount of regenerative discharge from a servo motor exceeds
the regenerative discharge capacity of the regenerative discharge
resistor incorporated in the corresponding servo amplifier, a separated
regenerative discharge resistor is needed.
If the motor regenerative discharge amount R obtained in Subsection
3.6.2 exceeds the corresponding value listed in Table 3.6.3 (a),
“Regenerative discharge capacity of the regenerative discharge
resistor incorporated in servo amplifiers,” use a separated regenerative
discharge resistor.
Table 3.6.3 (a) Regenerative discharge capacity of the regenerative
discharge resistor incorporated in servo amplifiers
Servo amplifier Capacity
A06B-6130-H003 50 W
A06B-6130-H004 130 W
The following table lists the separated regenerative discharge resistors
that are available.
Select a separated regenerative discharge resistor whose discharge
capacity satisfies your requirement.
Table 3.6.3(b) Regenerative discharge capacity of regenerative
discharge resistors installed separately from servo amplifiers
Separated regenerative
discharge resistor
Wind speed of 0
m/s
Wind speed
of 2 m/s
Wind speed
of 4 m/s
A06B-6089-H500 R = 200W R = 400 W R = 600 W
A06B-6089-H713 Incorporates a cooling fan motor. R = 800 W
A06B-6089-H714 Incorporates a cooling fan motor. R = 1200 W