20. FUNCTIONS FOR HIGH SPEED
CUTTING B–63522EN/02
NC FUNCTION
272
Specify G05 only in a block using normal CNC command format. Then
specify move data in the special format explained below. When zero is
specified as the travel distance along all axes, normal CNC command
format can be used again for subsequent command specification.
Host computer
CNC
Remote buffer
RS–232C / RS–422
S Binary input operation enabled : G05;
Binary input operation disabled : The travel distance along
all axes are set to zero.
Data format for binary input operation
⋅⋅⋅⋅
Data
sequence
1st axis
2nd axis
Nth axis
Check byte
Byte
High byte
High byte
High byte
Low byte
Low byte
Low byte
In the data format for binary input operation, the travel distance along
each axis (2 bytes) per unit time is specified. The travel distances along
all axes are placed sequentially from the first axis, then a check byte is
added. (The data length for one block is [2 x N + 1] bytes).
All data must be specified in binary.
20.5.2
High–speed Remote
Buffer A (G05)
(Only at 1–path
Control)
Format