B–63522EN/02
30. DATA INPUT/OUTPUT
NC FUNCTION
403
The DNC1/Ethernet function allows remote control and monitoring of
CNCs from the personal computer. This function provides a software
library having a simpler function call format than the FOCAS1/Ethernet
function.
For details, refer to ”Ethernet Board/DATA SERVER Board Operator’s
Manual (B–63354EN)” and ”FANUC Personal Computer FA System
Windows NT Version Operator’s Manual (B–75044EN).”
The following NC data can be transferred by operation on the personal
computer:
D NC programs
D Directory information in part program storage
D NC file data
- Parameters
- Tool offset values
- Custom macro variables
D Alarm information
D NC system identification information
D PMC data
- Addresses G, F, Y, X, A, R, T, K, C, D
The following operations can be performed by operation on the personal
computer:
D Selecting NC programs
D Deleting NC programs
D External reset
The following operation can be performed by operation on the personal
computer:
D DNC operation
30.8.2
DNC1/Ethernet
Function
NC data transfer
Remote control
Operation