B–63522EN/02
2. LIST OF SPECIFICATIONS
GENERAL
24
Item
Series 21i
Series 210i
Series 210is
Series 18i
Series 180i
Series 180is
Series 16i
Series 160i
Series 160isSpecifications
TBMBTBMBMB5TBMB
Applicable spindle motor
FANUC SPINDLE MOTOR and
so on
f f f f f f f
Applicable spindle amplifier
FANUC SERVO AMPLIFIER
a/ai series
l l l l l l l
Applicable spindle amplifier
Analog interface l l l l l l l
Control unit supply voltage 24VDC"10% F F F F F F F
Ambient temperature around the
LCD–mounted type control unit,
stand–alone type display
Operating: 0_C to 58_C
Non–operating: –20_C to 60_C
F F F F F F F
unit *8
Stand–alone type control unit
Operating: 0_C to 55_C
Non–operating: –20_C to 60_C
F F F F F F F
Ambient relative humidity
*8
Normal: 75% or less (no con-
densation)
Short period (within one month):
95% or less
(no condensation)
f f f f f f f
Vibration
Operating: 0.5G or less
Non–operating: 1G or less
f f f f f f f
Note) The items marked with *1 to *8 (including *1–1, *1–2, and *2–1) have notes added. These notes are pro-
vided at the end of this chapter.
NOTES ON THE SPECIFICATION LIST
*1 On the 160i, 180i, 210i, 160is, 180is, and 210is, restrictions may be imposed.
*1–1 This function can not used with the 160is, 180is, or 210is.
*1–2 This function cannot be used in the following case:
D 160i/180i/210i/160is/180is/210is.
D Construction of connecting with PC via HSSB and not attaching MDI to the CNC side.
*2 Only for the 160i, 180i, and 210i.
*2–1 Only for the 160i, 180i, 210i, 160is, 180is, and 210is.
*3 For two paths with one CPU on the 18i, up to three axes are permitted for both paths in total.
*4 For the 16i and 18i, up to 6MB for one–path control, and up to 4MB for two–path control.
For the 21i, up to 4MB.
*5 The actual storage size varies slightly depending on the number of registered programs and
their sizes.
*6 An LCD is created using high–precision processing technology. On the LCD, some points
may be always on; others may be always off. This status is caused due to the structure of
the LCD and indicates no failure.
*7 For the descriptions related to hardware of the LCD–mounted type 160is/180is/210is, see
Chapter II–35.
*8 For the descriptions related to CNC display units with PC functions that are used for the
160i/180i/210i, see Chapter II–35.
For the descriptions related to CNC display units with is series CNC that are used for the
160is/180is/210is, see Chapter II–35.