B–63522EN/02
A. RANGE OF COMMAND VALUE
APPENDIX
497
Increment system
IS–B IS–C
Least input increment 0.001 deg 0.0001 deg
Least command increment ±0.001 deg ±0.0001 deg
Max. programmabledimension ±99999.999 deg ±9999.9999 deg
Max. rapid traverse *1 240000 deg/min 100000 deg/min
Feedrate range *1 1 to 240000 deg/min 1 to 100000 deg/min
Incremental feed 0.001, 0.01, 0.1, 1 deg/step 0.0001, 0.001, 0.01, 0.1 deg/step
NOTE
*1 The feedrate range shown above are limitations depending
on CNC interpolation capacity.
As a whole system, limitations depending on servo system
must also be considered.
Rotation axis