Watch Dog
Alarm 2
ERR lit E9 or
"."(dot) of
X10
1 0 -
I/O Link system alarm is occurred on the
host CNC.
Replace the converter unit.
I/O Link
slave watch
dog
ERR lit E6 - - -
I/O Link system alarm is occurred on the
host CNC.
This error is occurred when the power of
the other I/O Link slave unit is off, or the
disconnection of I/O Link cables.
It may be communication error caused
by noise.
I/O Link
RAM fail
ERR lit E7 - - -
I/O Link system alarm is occurred on the
host CNC.
Replace the converter unit.
note 1) When the protected mode, the smallest address number from configuration mismatch
slaves is displayed. When the configuration mode, nothing is displayed.
note 2) The alarm of the converter unit should be watched and display by the ladder program.
note 3) When the ERR LED is lit (the alarm of converter unit is occurred), DO is off and DI is
also off.
note 4) When the AS-i communication is failed, watch dog alarm is occurred on the slave unit.
Please refer to the manual of slave units about the behavior of output when the slave watch
dog alarm is occured. The behavior of output signal is according to the type of slave unit or
parameter value.
note 5) When the 7 segments LED indicates “E1”, the configuration may be failed, set to
configure again below.
Caution) If the 7 segments LED indicates “E1”, CNC does not start.
AS-I converter is manufactured from June 2005 with this function (Lot No.2005.06).
This function method is not applicable in unit shipped before June 2005. In that case, replace
the converter unit.
EDIT
SHEET
DRAW. NO.
CUST
TITLE
30/33
DESCRIPTION DESIG. DATE
04 05.06.07 Yamana Out of frame #4 is added
FANUC I/O Link-AS-i Converter
Connecting manual
-80906E
#4
Turn off the power
Pressing the SET switch, turn on the power again.
The 7 segments LED indicates “88”. (Keep to press the set switch)
After the 7 segments LED does not indicate “88”, return the set switch
Press the SET switch to change to the protected mode again