PROGRAMMING
B–64124EN/01
18. MEMORY OPERATION USING
FS10/11 TAPE FORMAT
375
18
MEMORY OPERATION USING FS10/11 TAPE FORMAT
Memory operation of the program registered by FS10/11 tape format is
possible with setting of the setting parameter (No. 0001#1).
Data formats for cutter compensation, subprogram calling, and canned
cycles are different between this Series and Series 10/11. The Series 10/11
data formats can be processed for memory operation.Other data formats
must comply with this Series. When a value out of the specified range for
this Series is registered, an alarm occurs. Functions not available in this
Series cannot be registered or used for memory operation.
Offset numbers are specified by address D in the Series 10/11. When an
offset number is specified by address D, the modal value specified by
address H is replaced with the offset number specified by address D.
If a subprogram number of more than four digits is specified, the four
low–order digits are regarded as the subprogram number. If no repeat
count is specified, 1 is assumed.
Table 18 (a) Subprogram call data format
CNC
Data format
Series 10/11 M98 Pfffff Lffff ;
P : Subprogram number
L : Repetition count
Series 0i
The Series 10/11 and Series 16/18/21 use different addresses for the repeat
count for canned cycles as listed in Table 18 (b).
Table 18 (b) Address for times of repetition of canned cycle
CNC
Address
Series 10/11 L
Series 0i K
General
Explanations
D Address for the cutter
compensation offset
number
D Subprogram call
M98 Pffff jjjj ;
Repetition count Subprogram number
D Address for the canned
cycle repetition count