OPERATION
B–64124EN/01
11. SETTING AND DISPLAYING DATA
667
Compensation data items are classified by D code or H code and by
geometry or wear.
The entry of compensation values may be disabled by setting bit 0 (WOF)
and bit 1 (GOF) of parameter 3290.
And then, the input of tool compensation values from the MDI can be
inhibited for a specified range of offset numbers. The first offset number
for which the input of a value is inhibited is set in parameter No. 3294.
The number of offset numbers, starting from the specified first number,
for which the input of a value is inhibited is set in parameter No. 3295.
Consecutive input values are set as follows:
1) When values are input for offset numbers, starting from one for which
input is not inhibited to one for which input is inhibited, a warning is
issued and values are set only for those offset numbers for which input
is not inhibited.
2) When values are input for offset numbers, starting from one for which
input is inhibited to one for which input is not inhibited, a warning is
issued and no values are set.
D Tool offset memory
D Disabling entry of
compensation values