OPERATION11. SETTING AND DISPLAYING DATA
B–64124EN/01
688
⋅ Deleting a tool group : 7–4
⋅ Deleting tool data (T, H, or D code) : 7–5
⋅ Skipping a tool : 7–6
⋅ Clearing the life count
(resetting the life) : 7–7
7–1 Setting the life count type, life value, current life count, and tool
data (T, H, or D code)
(1)Position the cursor on the data item to be changed.
(2)Enter a desired value.
(3)Press the softkey
[INPUT].
7–2 Adding a tool group
(1) In step 3, select a group for which no data is set and display the
editing screen.
(2) Enter tool numbers.
(3) Press soft key
[INSERT].
⋅ In this case, the type of the life counter is determined by the setting of
LTM (No. 6800#2), and 0 is set in both the life expectancy and life
counter.
⋅ 0 is set in both the H code and D code.
⋅ The cursor remains on the tool number until the T code is specified.
7–3 Adding a tool number
(1) Move the cursor to the tool data (T, H, or D code) after which a new
number is to be added.
(2) Enter the tool number.
(3) Press soft key
[INSERT].
Example),Inserting tool No. 1500 between No. 1 and No. 2.
NO. STATE T–CODE H–CODE D–CODE
01 * 0034 11 5
02 # 0078 0 33
Move the cursor to 5 in D–CODE column and press soft key
[INSERT].
NO. STATE T–CODE H–CODE D–CODE
01 * 0034 11 5
02 1500 00
03 # 0078 0 33