OPERATION8. DATA INPUT/OUTPUT
B–64124EN/01
574
Outputting parameters
1 Press soft key [PARAM] on the ALL IO screen, described in Section
III–8.10.1.
2 Select EDIT mode.
3 Press soft key
[(OPRT)]. The screen and soft keys change as shown
below.
READ/PUNCH (PARAMETER) O1234 N12345
MDI
*
* * * * * * * * * * * *
12:34:56
READ PUNCH
I/O CHANNEL 1 TV CHECK OFF
DEVICE NUM. 0 PUNCH CODE ISO
BAUDRATE 4800 INPUT CODE ASCII
STOP BIT 2 FEED OUTPUT FEED
NULL INPUT (EIA) NO EOB OUTPUT (ISO) CR
TV CHECK (NOTES) ON
(0:EIA 1:ISO)>1_
4 Press soft key [PUNCH], then [EXEC].
The parameters are output, and the OUTPUT” indicator blinks at the
lower–right corner of the screen. Upon the completion of output, the
OUTPUT” indicator is cleared from the screen.
To cancel output, press soft key
[CAN].
Procedure
EXECCAN