OPERATION8. DATA INPUT/OUTPUT
B–64124EN/01
592
When this screen is displayed, the program data item is selected. Select
other items by pressing the soft keys that appear when the user presses
next–menu key
.
MACRO (OPRT)WORKPITCH
When a data item other than program is selected, the screen displays only
a file directory.
A data item is indicated, in parentheses, on the title line.
READ/PUNCH (PARAMETER)
No. FILE NAME SIZE DATE
O0001 N00001
0001 O0222 332010 96/04/06
0002 O1003 334450 96/05/04
0003 MACROVAR.DAT 653400 96/05/12
0004 O0003 334610 96/05/04
0005 O0001 334254 96/06/04
0006 O0002 333750 96/06/04
0007 CNCPARAM.DAT 334453 96/06/04
~ ~
Program directory display does not match bit 0 (NAM) of parameter No.
3107, or bit 4 (SOR) of parameter No. 3107.
Display the following soft keys with soft key
[(OPRT)].
F SRH DELETEN READF READ PUNCH
The operation of each function is the same as on the directory (memory
card) screen. Soft key
[O SET], used for program number setting, and the
”PROGRAM NUMBER =” indication are not displayed for data items
other than program.
[F SRH] : Finds a specified file number.
[F READ] : Reads a specified file number.
[PUNCH] : Writes a file.
[N READ] : Reads a file under a specified file name.
[DELETE] : Deletes a specified file number.
NOTE
With a memory card, RMT mode operation and the
subprogram call function (based on the M198 command)
cannot be used.
Explanations
D Each data item
D Program directory
display