APPENDIXG. ALARM LIST
B–64124EN/01
854
Number ContentsMessage
203 PROGRAM MISS AT RIGID
TAPPING
In the rigid tapping, position for a rigid M code (M29) or an S
command is incorrect. Modify the program.
204 ILLEGAL AXIS OPERATION In the rigid tapping, an axis movement is specified between the rigid
M code (M29) block and G84 (G74) block. Modify the program.
205 RIGID MODE DI SIGNAL OFF Rigid tapping signal (DGNG061 #1) is not 1 when G84 (G88) is
executed though the rigid M code (M29) is specified.
Consult the PMC ladder diagram to find the reason the signal is not
turned on.
206 CAN NOT CHANGE PLANE
(RIGID TAP)
Plane changeover was instructed in the rigid mode.
Correct the program.
207 RIGID DATA MISMATCH The specified distance was too short or too long in rigid tapping.
210 CAN NOT COMAND M198/M99 1) M198 and M99 are executed in the schedule operation. Or M198
is executed in the DNC operation.
2) In a multiple repetitive pocketing canned cycle, an interrupt macro
was specified, and M99 was executed.
212 ILLEGAL PLANE SELECT The arbitrary angle chamfering or a corner R is commanded or the
plane including an additional axis. Correct the program.
213 ILLEGAL COMMAND IN
SYNCHRO–MODE
Any of the following alarms occurred in the operation with the simple
synchronization control.
1) The program issued the move command to the slave axis.
2) The program issued the manual continuous feed/manual handle
feed/incremental feed command to the slave axis.
3) The program issued the automatic reference position return com-
mand without executing the manual reference position return after
the power was turned on.
4) The difference between the position error amount of the master and
slave axes exceeded the value specified in parameter No. 8313.
214 ILLEGAL COMMAND IN
SYNCHRO–MODE
Coordinate system is set or tool compensation of the shift type is
executed in the synchronous control. Correct the program.
224 RETURN TO REFERENCE POINT Reference position return has not been performed before the auto-
matic operation starts. Perform reference position return only when
parameter ZRN
X
(No.1005#0) is 0.
231 ILLEGAL FORMAT IN G10 OR L50 Any of the following errors occurred in the specified format at the
programmable–parameter input.
1) Address N or R was not entered.
2) A number not specified for a parameter was entered.
3) The axis number was too large.
4) An axis number was not specified in the axis–type parameter.
5) An axis number was specified in the parameter which is not an axis
type.
6) An attempt was made to reset bit 4 of parameter 3202 (NE9) or
change parameter 3210 (PSSWD) when they are protected by a
password. Correct the program.
232 TOO MANY HELICAL AXIS
COMMANDS
Three or more axes (in the normal direction control mode two or more
axes) were specified as helical axes in the helical interpolation mode.
233 DEVICE BUSY When an attempt was made to use a unit such as that connected via
the RS–232–C interface, other users were using it.
239 BP/S ALARM While punching was being performed with the function for controlling
external I/O units ,background editing was performed.
240 BP/S ALARM Background editing was performed during MDI operation.
253 G05 IS NOT AVAIRABLE Binary–input operation with a high–speed remote buffer (G05) or
high–speed cycle machining (G05) has been specified in look–ahead
control mode (G08P1). Before attempting to specify these
commands, first specify G08P0; to cancel look–ahead control mode.