OPERATION11. SETTING AND DISPLAYING DATA
B–64124EN/01
678
5 To display the workpiece origin offset setting screen, press the
chapter selection soft key
[WORK].
NO. DATA NO. DATA
00 X 0.000 02 X 0.000
(EXT) Y 0.000 (G55) Y 0.000
Z 0.000 Z 0.000
01 X 0.000 03 X 0.000
(G54) Y 0.000 (G56) Y 0.000
Z 0.000 Z 0.000
WORK COORDINATES O1234 N56789
(G54)
> Z100. S 0 T0000
MDI **** *** *** 16:05:59
[ NO.SRH ] [ MEASUR ] [ ] [ +INPUT ] [ INPUT ]
6 Position the cursor to the workpiece origin offset value to be set.
7 Press the address key for the axis along which the offset is to be set
(Y–axis in this example).
8 Enter the measured value (α) then press the
[MEASUR] soft key.
9 Move the reference tool manually until it touches surface B of the
workpiece.
10 Retract the tool without changing the X coordinate.
11 Measure distance β then enter the distance at X on the screen in the
same way as in steps 7 and 8.
Offsets for two or more axes cannot be input at the same time.
This function cannot be used while a program is being executed.
Limitations
D Consecutive input
D During program
execution