B–63380EN/02
4. DESCRIPTION OF PARAMETERS
145
#7
5200
#6
FHD
#5
PCP
#4
DOV
#3
SIG
#2
CRG
#1
VGR
#0
G84
[Data type] Bit
G84 Method for specifying rigid tapping
0 : An M code specifying the rigid tapping mode is specified prior to the
issue of the G84 (or G74) command. (See parameter No.5210).
1 : An M code specifying the rigid tapping mode is not used. (G84
cannot be used as a G code for the tapping cycle; G74 cannot be used
for the reverse tapping cycle.)
VGR Any gear ratio between spindle and position coder in rigid tapping
0 : Not used (The gear ratio is set in parameter No.3706.)
1 : Used (The gear ratio is set by parameters Nos. 5221 through 5224 and
5231 through 5234.)
NOTE
For serial spindles, set this parameter to 0 when using the
DMR function for position coder signals on the spindle side.
CRG Rigid mode when a rigid mode cancel command is specified (G80, G01
group G code, reset, etc.)
0 : Canceled after rigid tapping signal RGTAP is set to “0”.
1 : Canceled before rigid tapping signal RGTAP is set to “0”.
SIG When gears are changed for rigid tapping, the use of SIND <G032 and
G033> is
0 : Not permitted.
1 : Permitted.
DOV Override during extraction in rigid tapping
0 : Invalidated
1 : Validated (The override value is set in parameter No.5211.)
PCP Rigid tapping
0 : Used as a high–speed peck tapping cycle
1 : Not used as a high–speed peck tapping cycle
FHD Feed hold and single block in rigid tapping
0 : Invalidated
1 : Validated
4.17
PARAMETERS OF
RIGID TAPPING