B–63380EN/02
4. DESCRIPTION OF PARAMETERS
71
Controlled
axis
number
1
2
3
4
Program
axis name
No.1020
X
Y
Z
A
Servo axis
number
No.1023
1
3
4
2
Interface
type
Fast/Slow
F
F
S
S
CNC
2–axis
amplifier
1–axis
amplifier
1–axis
amplifier
X (Fast)
A (Slow)
Y (Fast)
Z (Slow)
PM1 The first pulse module is:
0 : Not used.
1 : Used.
PM2 The second pulse module is:
0 : Not used.
1 : Used.
NOTE
When automatic setting mode is selected for FSSB setting
(when the FMD parameter (bit 0 of parameter No.1902) is
set to 0), parameter No.1905 is automatically set when input
is performed with the FSSB setting screen. When manual
setting 2 mode is selected for FSSB setting (when the FMD
parameter (bit 0 of parameter No.1902) is set to 1),
parameter No.1905 must be set directly. When a pulse
module is used, a connector number must be set in the
corresponding parameter (No.1936 or No.1937).
1910 Address conversion table value for slave 1 (ATR)
1911 Address conversion table value for slave 2 (ATR)
1912 Address conversion table value for slave 3 (ATR)
1913 Address conversion table value for slave 4 (ATR)
1914 Address conversion table value for slave 5 (ATR)
1915 Address conversion table value for slave 6 (ATR)
1916 Address conversion table value for slave 7 (ATR)
1917 Address conversion table value for slave 8 (ATR)
1918 Address conversion table value for slave 9 (ATR)
1919 Address conversion table value for slave 10 (ATR)
NOTE
After these parameters have been set, the power must be
turned off then back on for the settings to become effective.
[Data type] Byte
[Valid data range] 0 to 3, 16, 40, 48