B-64223EN/01-03
Title
Draw
Ed. Date Design Description
Date Design. Apprv.
2/4
page
2.SPECIFICATIONS CONNECTION B-64223EN-01
2.3.1.3 Power-on/off of the PANEL i for AUTOMOTIVE with I/O Link
The PANEL i for AUTOMOTIVE with I/O Link operates as a slave I/O
device of I/O Link.
For this reason, the power to the PANEL i must be turned on or off at the
same time when the power to the CNC control unit or cell controller
having the I/O Link master functions is turned on or off. (For the
allowable time difference, refer to the relevant CNC connection manual.
An example for the Series 16i is shown below.)
If this power-on/off sequence is not followed, an error may occur in the
CNC control unit or cell controller or the I/O Link adapter built into the
PANEL i may not normally be connected to I/O Link.
Example 1
P ow er-on/off sw itc h
Serial
communication
AC input
UPS
Power
supply
unit 1
I/O Link
Power
supply
unit 2
PANEL
i
for
AUTOMOTIVE
DC24IN
I/O LINK
RS232C
CNC control unit
DC24IN
I/O LINK
Another I/O device
DC24IN
I/O LINK
For a connection like this example, be careful about the power-on/off
timing of individual units.
- Example for the Series 16i
• Power-on timing
Up to 200ms Up to 500ms
Power to the CNC and
I/O device
Power to the PANEL
i
ON
OFF
ON
OFF
(Applicable page: page 15)