4.CONNECTION TO PERIPHERAL CONNECTION B-64223EN/01
- 58 -
4.11.2 Twisted-Pair Cable Specification
Cable Connection
The cable used for connection between the 10BASE-T/100BASE-TX
interface CD38U and the hub is connected as follows:
CD38U
1TX+
2TX-
3RX+
4
5
6RX-
7
8
RJ-45
modular connector
Max. 100m
HUB
1 TX+
2 TX-
3 RX+
4
5
6 RX-
7
8
TX+
TX-
RX+
RX-
1
2
3
6
Shield
CD38U
TX+
TX-
RX+
RX-
1
2
3
6
NOTE
1 The cable can be up to 100 m long (for the
FANUC- recommended cable for movable
sections, up to 50 m). Do not make the cable
longer than necessary.
2 There are two types of commercially available
cables: straight-connection and cross-connection
types. Select an appropriate cable according to
the purpose.
Cable Materials
Many cables without a shield (UTP cables) are commercially available
as twisted pair cables conforming to 10BASE-T or 100BASE-TX.
To improve noise immunity in factory automation environments,
however, be sure to use twisted pair cables (STP cables) with a
common shield in category 5.
Recommended cables (for fixed parts)
Manufacturer Specification Remark
Furukawa Electric Co., Ltd. DTS5087C-4P Twisted wires
Nissei Electric Co., Ltd. F-4PFWMF Single-wire cable