B-64223EN/01-03
Title
Draw
Ed. Date Design Description
Date Design. Apprv.
3/4
page
• Power-off timing
ON
OFF
ON
OFF
Up to 500ms
Power to the CNC and
I/O device
Power to the PANEL
i
Example 2
PANEL
i
for AUTOMOTIVE
DC24IN
I/O LINK
RS232C
CNC control unit
DC24IN
I/O LINK
Serial
communication
C input
Power
supply
unit
UPS
I/O
Link
Another I/O device
DC24IN
I/O LINK
Power-on/off switch
Example 3
In order to switch on/off the PANEL i for Automotive and other I/O link
devices including CNC controller separatly, the PANEL i for Automotive
with I/O Link adapter should be connected as last I/O Link slave device
(farthest from CNC controller) on the I/O Link line. (Please refer the next
page)
By the above connection, it becomes possibe to switch off the CNC and
other I/O link devices without switching off Panel i for Automotive.
Please pay attention that CNC and other I/O link devices should be
switch off when the PANEL i for Automotive is switched off, even if the
PANEL i for Automotive is connected as last I/O Link slave device .
(Applicable page: page 16)
01 05.02.08 Kumakura Example 3 is added.