B-64223EN/01 CONNECTION 4.CONNECTION TO PERIPHERAL
- 59 -
Inquiries
Manufacturer Contact address
Furukawa Electric Co., Ltd.
Sales Headquarters
2-6-1 Marunouchi, Chiyoda-ku. Tokyo 100-8322
TEL: 03-3286-3126 FAX: 03-3286-3979
Nissei Electric Co., Ltd.
Machida Branch
3F MU Bldg., 1-9-1 Minami-narise, Machida City,
Tokyo 194-0045
TEL: 0427-29-2531
Overseas Sales Office IWATANI International Corporation
Tokyo Head Office
21-8 Nishi-shinbashi 3-chome, Minato-ku,
TOKYO, 105-8458, JAPAN
TEL: 03-5405-5810
Telex: 2524256 IWATYO J
NOTE
These recommended cables for fixed parts must
not be used for movable sections. Be sure to use
the following recommended cables for movable
sections.
Recommended cable (for movable sections)
Manufacturer Specification Remark
Oki Electric Cable AWG26 4P TPMC-C5-F(SB) Dedicated to FANUC
products
Cable specification (FANUC original product, with no connector)
Drawing number: A66L-0001-0453
Manufacturer: Oki Electric Cable Co., Ltd.
Specification
• Electrical characteristic:
Complying with EIA/TIA 568A categories 3
and 5
The length of the cable to the hub must be kept
within 50 m because of its attenuation
performance.
• Structure : Common-shield braided cable with drain wire
The conductors of the cable are AWG26
annealed-copper strand wire, with a sheath 0.8
mm thick and an outer diameter of 6.7±0.3 mm
• Fire resistance : UL1581 VW-1
• Oil resistance : As per FANUC's internal standard (Equivalent
to conventional oil-resistant electrical cable)
• Flex resistance : Million or more bending cycles with a bending
radius of 50 mm (U-shaped bend test)
• UL style No. : AWM20276 (80°C/30V/VW-1)
NOTE
Use the TM21CP-88P(03) connector made by
Hirose Electric Co., Ltd. to this cable.