OPERATION
B–63684EN/01
6. SAFETY FUNCTIONS
463
After safety zone values are set automatically, they can be displayed on
the safety zone screen as shown below. With this screen, the user can
check whether the set values are valid.
SAFETY ZONE (ABSOLUTE) O0017 N01234
AREA #1 AREA #3
X2= 100.000 X2= 1000.000
X1= 200.000 X1= 1150.000
Y = 100.000 Y = 110.000
AREA #2 AREA #4
X2= 500.000 X2= 1400.000
X1= 600.000 X1= 1550.000
Y = 100.000 Y = 110.000
TOOL ZONE
X = 5.000
Y = 10.000
)_
MEM **** *** *** 11:32:41
[ TOOL ][ ][ SAFETY ][ ][ (OPRT) ]
SAFETY ZONE (ABSOLUTE) O0017 N01234
AREA #1 AREA #3
W = 100.000 W = 100.000
X = 200.000 X = 1150.000
Y = 100.000 Y = 110.000
AREA #2 AREA #4
W = 100.000 W = 100.000
X = 600.000 X = 1550.000
Y = 100.000 Y = 110.000
TOOL ZONE ZONE NUMBER
X = 5.000 N = 2
Y = 10.000
)_
MEM **** *** *** 11:32:41
[ TOOL ][ ][ SAFETY ][ ][ (OPRT) ]
NOTE
The display items of type B are as follows:
W : Workpiece holder width
X : Workpiece holder central position relative to the tool
center
Y : Workpiece holder tip position relative to the tool center
6.5.6
Displaying the Safety
Zones and Tool Zone
Screen
Type A
Screen
Type B