B-65222EN/03 START-UP 4.PARAMETER SETTING
- 157 -
(3) Start initialization.
#7 #6 #5 #4 #3 #2 #1 #0
INITIAL SET BIT PRMC DGPR PLC0
( Note)
Start initialization (Keep the NC power on until step (10).)
DGPR (#1) = 0 Automatically set to 1 after initialization.
NOTE
Once initialization has been completed,
automatically set bit 3 (PRMC) for initialization to 0.
(4) Specify the motor ID No.
Based on the motor model and drawing number (A06B-)
information, select the motor type number of a linear motor used.
Model name Drawing number Motor type number
300D/4 0421-B801 124
600D/4 0422-B801 125
900D/4 0423-B801 126
1500A/4 0410-B901 90
3000B/2 0411-B911, 0411-B901 91
3000B/4 0411-B811 120
6000B/2 0412-B911, 0412-B901 92
6000B/4 0412-B811 121
9000B/2 0413-B911, 0413-B901 93
9000B/4 0413-B811 122
15000C/2 0414-B901 94
15000C/3 0414-B811 123
* Motor type numbers are for servo HRV1 driven by 200 V.
NOTE
Servo axes are controlled in groups of two axes. So,
for successive servo control numbers (odd number
and even number), motor type number unified for
servo HRV1 or for servo HRV2 or HRV3 must be