4.PARAMETER SETTING START-UP B-65222EN/03
- 170 -
Parameter setting procedure (5)
Procedure (5) supplements descriptions about application of servo
HRV2 for linear motors.
When servo HRV2 is applied to increase the current loop gain of a
linear motor, it is necessary to set the following parameter, because
linear motors have a higher current gain compared with rotational
motors. This parameter setting must be done whenever the absolute
value of the current loop proportional gain (PK2) becomes higher
than 16000 (as a rule of thumb) after application of servo HRV2.
#7 #6 #5 #4 #3 #2 #1 #0
1750 - PK12S2
2210 -
PK12S2 (#2) Specifies whether to use the quadruple current loop gain function.
0: Not to use
1: To use ← To be set
When setting this function to ON, re-set the current gain parameters
(PK1 and PK2) to one-fourth.
Table 4.14.1 (d) Current gain parameter setting when servo HRV2 is applied
Typical setting
Setting after servo HRV2 is
applied
Model
name
PK12S2 PK1 PK2 PK12S2 PK1 PK2
300D/4 0 526 -2141 0 421 -3426
600D/4 0 717 -3333 0 574 -5332
900D/4 0 390 -2009 0 312 -3214
1500A/4 0 1890 -7180 0 1512 -11488
3000B/2 0 4804 -14453 1 961 -5782
3000B/4 0 1620 -11180 1 324 -4472
6000B/2 0 4804 -13138 1 961 -5253
6000B/4 0 2626 -10051 1 525 -4020
9000B/2 0 5036 -16000 1 1008 -6400
9000B/4 0 4944 -11831 1 989 -4732
15000C/2 1 1420 -5600 1 1136 -8960
15000C/3 0 2392 -8448 1 478 -3379