B-65222EN/03 START-UP 4.PARAMETER SETTING
- 161 -
*1 If the number of position/velocity pulses does not fit one word,
set the following bit to 1.
#7 #6 #5 #4 #3 #2 #1 #0
1804 - PLC0
2000 -
PLC0 (#0) Specifies whether to use the number of velocity or position pulses
without modifying them, as follows:
0: Not to modify
1: Multiply by 10 ← To be set
*2 Because the number of position pulses exceeds 130,000, specify
the position pulse conversion coefficient (supported by Series
90B0).
2628 - Position pulse conversion coefficient (PSMPYL)
2185 -
Bit for multiplying the number of position/velocity pulses by ten
(PLC0) = 1
Number of pulses (PPLS) = 8000
Position pulse conversion coefficient (PSMPYL) = 2
Regard 160,000 pulses as: (8000*2)*10
*3-a Because the velocity loop proportional gain overflows, set the
following bit to 1 (supported by Series 90B0).
#7 #6 #5 #4 #3 #2 #1 #0
1740 - P2EX
2200 -
P2EX (#6) Velocity loop proportional gain (PK2V)
0: Standard format
1: Changes the format ← To be set
*3-b Because the dead zone compensation parameter overflows
internally, change it as follows:
1866 - Dead zone compensation (tilt) (PDDP)
2054 -
PDDP Dead zone compensation (tilt)
1894 (typical value for linear motor) → 1500