
2.SPECIFICATIONS SPECIFICATIONS B-65222EN/03
- 10 -
*1
Model
Item Symbol Unit
6000B/2 *9 6000B/4 9000B/2 *9
Cooling method(*2) - -
No
cooling
Air
cooling
Water
cooling
No
cooling
Air
cooling
Water
cooling
No
cooling
Air
cooling
Water
cooling
Maximum speed - m/s
2
(4)
4
2
(4)
Upper speed for the
maximum force
-m/s
1
(2)
2.2
1
(2)
Continuous force Fc N 1200 1440 2400 1200 1440 2400 1800 2160 3600
Maximum force Fp N 6000 6000 9000
Continuous output Oc kW
2.4
(4.8)
2.9
(5.8)
4.8
(9.6)
4.8 5.8 9.6
3.6
(7.2)
4.3
(8.6)
7.2
(14.4)
Maximum output Op kW
6.4
(13.5)
13.5
9.6
(20.3)
Continuous current Ic Arms 10.2 12.3 20.4 20.4 24.5 40.9 15.3 18.4 30.7
Maximum current Ip Arms 57 113 85
Maximum amplifier current - Ap 80 160 130
Force constant Kf N/Arms 117.4 58.7 117.4
Back electromotive force
constant
Ke Vrms/(m/s) 39.1 19.6 39.1
Armature resistance Ra Ω 1.11 0.278 0.74
Thermal time constant Tt min. 60 30 1 60 30 1 60 30 1
IC CODE(*4) - - 0A8 9A7A7 9W7A7 0A8 9A7A7 9W7A7 0A8 9A7A7 9W7A7
Coolant(*5) - - - Air Water - Air Water - Air Water
Flow rate - L/min - - 7.5 - - 7.5 - - 7.5
Recommended
pressure
- Mpa - - 0.42 - - 0.42 - - 0.5
Maximum
pressure
- Mpa - - 0.63 - - 0.63 - - 0.63
Cooling
conditions
(*3)
Required
cooling capacity
- W - - 1700 - - 1700 - - 2600
Magnetic attraction(*6) Fa N 18000 18000 27000
Weight of the coil slider(*7) W kg 23 23 34
Type of applicable magnet
plate(*8)
-- B B B
*1 Standard values at an ambient temperature of 25(C and a power supply voltage of 200 V
The values may vary depending on the ambient temperature, digital servo software, parameters, power supply voltage, amplifier specifications, and others.
*2 When "no cooling" is used, the cooling tube in the coil slider is not used. To use "air cooling" or "water cooling," a forced cooling system using the internal
cooling tube is required.
*3 When "no cooling" or "air cooling" is used, the thermal loss differs depending on the materials of parts around the coil slider and machine configuration.
According to the thermal loss, the rating may vary.
*4 Conforms to EN60034-6. IC code "0A8" for "no cooling" is cooling for a movable coil slider. For cooling for a movable magnet plate, the IC code is "0A0".
*5 Primary coolant for forced cooling (coolant for directly cooling the coil slider)
"Air" means ordinary industrial compressed air. "Water" means ion exchanged water (including 5% rust inhibitor).
*6 Approximate magnetic attraction between the coil slider and magnet plate when there is a 0.5-mm mechanical gap between the coil slider and magnet
plate
The value varies depending on the size of the gap.
*7 When an incremental linear encoder is used, the weight of the magnetic pole sensor is added. For details, see the subsection "Magnetic Pole Sensor"
below.
*8 The type of applicable magnet plate differs depending on the motor model. For details, see the subsection "Magnet Plate" below.
*9 Can be driven by 400 V input (FANUC HV amplifier). The values in parentheses in the table indicate data when the motor is driven with 400 V. Drive
parameters dedicated to 400 V are required.