title
Sheet
Draw. No.
FANUC LINEAR MOTOR series
DESCRIPTIONS (Detector)
15/15
FANUC LTD
B-65222EN/03-005
Description Desig. Date Edit.
02 03.04.08 Miyamoto Add this page Taniguchi
Parameter No. Parameters
FS15 i FS16 i
etc.
Conversion of Parameters
Integral Gain PK1V 1855 2043 (primary setting value) /6 (1)
Proportional Gain PK2V 1856 2044 (primary setting value) /6 (1)
Observer POA1 1859 2047 (primary setting value) x 6 (2)
PPMAX 1865 2053 (primary setting value) x 6 Dead-band
Compensation
PDDP 1866 2054 (primary setting value) /6
MFWKCE 1736 2128 (primary setting value) /6 Magnetic Flux
Weaken
Compensation
MFWKBL 1752 2129 (the quotient that primary setting value
/256) x 6 x 256
+ (the remainder that primary setting
value /256)
(1)
There is a possibility that the value of PK1V or PK2V becomes too small. In this case, divide
the velocity gain in servo adjusting display by n, and multiply the value of PK1V or PK2V by
n.
(2)
When the value of POA1 overflows from one word (=16 bits), it divides by 10 and set with
negative sign. And if it still overflows, it set to zero. (In this case the function of observer is not
available.)